OCD-H SERIES

blank

PRODUCTS

OCD-H SERIES

The regeneration process at OCD-H series blower purge heated desiccant dryers provide by centrifugal blower and high efficient heater. By this way compressed air which obtain with cost does not use for service air. The complete automatic drying system use blower to pull ambient air for passing through heater. The hot air stream flows opposite with drying flow direction. The hot air which reach above of 200 °C temperature, provide re-generation for desiccant bed and take away completely the moisture that hold by desiccant. For providing real energy save advanced control system dew point meter measure continuously dew point for performing heating and re-generation processes.


All heating section isolated for providing efficiency.
 

 

STANDARD PROPERTIES OF OCD-H SEIRES BLOWER PURGE HEATED DESICCANT DRYERS
- Displaying and adjustment dew point by dew point meter
- Computer control
- Display working mode, alarms and pressure
- Remote control
- Low pressure alarm
- Minimum pressure valve with indicator
- High pressure safety and alarms
OCD-H series dryers include all properties of OCD series Heatless dryers, OCD - H can work at 3 different working modes as OCD-H or inside heated or OCD

OCD-H SERIES BLOWER PURGE HEATED DESICCANT AIR DRYERS

MODEL AIR FLOW CONNECTION DIAMETER (inch) PRESSURE DROP (mbar) DEW POINT ˚C MAX. INTEL TEMPERATURE ˚C REQUIRED POWER (kw)
m³/h m³/min cfm
OCD-H 850 850 14,2 500,65 2” -130 -70 50 6,5
OCD-H 1000 1000 16,2 589,00 2” -130 -70 50 7,5
OCD-H 1250 1250 20,8 736,25 DN 80 -130 -70 50 8
OCD-H 1500 1500 25,0 883,50 DN 80 -130 -70 50 10
OCD-H 1800 1800 30,0 1060,20 DN 80 -130 -70 50 12
OCD-H 2200 2200 36,6 1295,80 DN 80 -130 -70 50 17
OCD-H 2700 2700 45,0 1590,30 DN 80 -130 -70 50 19
OCD-H 3200 3200 53,3 1884,80 DN 100 -130 -70 50 20
OCD-H 3600 3600 60,0 2120,40 DN 100 -130 -70 50 26
OCD-H 4400 4400 73,3 2591,60 DN 100 -130 -70 50 28
OCD-H 5000 5000 83,3 2945,00 DN 125 -130 -70 50 33
OCD-H 6300 6300 105,0 3710,70 DN 150 -130 -70 50 35
OCD-H 7200 7200 120,0 4240,80 DN 150 -130 -70 50 40
OCD-H 8800 8800 146,6 5183,20 DN 150 -130 -70 50 56
OCD-H 10800 10800 180,0 6361,20 DN 200 -130 -70 50 75

Air flows mentioned according to ISO 1217 standard at 20° C ambient temperature and 1 bar inlet pressure.

 

 